PNEUMATIC CONVEYING

SPECIAL PARTS QUICKFIX SYSTEM

HMAAUI PN TM E N UÜ

ESSER TWIN 700 Adapter - Fixed flange WN Rd6a/01A/PN10 to Quick-Fix Double-layered pipes. Inner wall hardened up to 63 HRC. Thick-walled design. Available from nominal diameters DN80 to DN150.

Pneumatic operating pressure up to 10 bar / test pressure up to 20 bar.

Wall thickness inside+outside (mm)

Nom. Size (ND)

Part No. / Drawing / Reference

Pneu. NP (Bar)

Inlet (Rd6a / A)

Weight (kg/m)

Length (mm)

Outlet

Version

200 < L < 6000

Fixed flange BC.Ø253, 8 x Ø18

Grounding lugs

125 1-125-114-0210-00 5,0+3,2 38,5

6,0QFN 8

Further nominal sizes or other connection types on request.

ESSER TWIN 700 Adapter - QuickFix to fixed flange WN Rd6a/01A/PN10

Double-layered pipes. Inner wall hardened up to 63 HRC. Thick-walled design. Available from nominal diameters DN80 to DN150. Pneumatic operating pressure up to 10 bar / test pressure up to 20 bar.

Wall thickness inside+outside (mm)

Nom. Size (ND)

Part No. / Drawing / Reference

Pneu. NP (Bar)

Outlet (Rd6a / A)

Weight (kg/m)

Length (mm)

Inlet

Version

200 < L < 6000

Fixed flange BC.Ø207, 8 x Ø18

Grounding lugs

80 1-0080-114-0067-00 3,6+3,6

22

4,0QF

10

Further nominal sizes or other connection types on request.